CLASP

Making appliance energy efficiency the new global standard

Germany | Heating & Air Conditioning, Space Heater | Residential

Label Endorsement, Under Revision

Umweltbundesamt (Federal Environment Agency)

Economy

Product

    • Product Group: Heating & Air Conditioning
    • Product Type: Space Heater
  • Sector: Residential
  • Fuel: Gas

Scope

Low-emission and Energy-saving Gas-fired Calorific-Value Heating Devices

These Basic Criteria apply to gas-fired calorific-value appliances
a) according to DIN 4702, Part 6, with a nominal thermal output of up to and including 70 kW designed for the use of natural gas the exhaust gases of which are discharged via an over-roof exhaust-gas system according to DIN 181601) approved by the building inspection authorities.
b) according to DIN 3368, Parts 7 and 8, with a nominal thermal output of up to and including 70kW designed for the use of natural gas the exhaust gases of which are discharged via an over-roof exhaust-gas system approved by the building inspection authorities or via an exhaust-gas pipe tested together with the appliance.
c) according to DIN EN 677 with a nominal heat load of up to and including 70kW designed for the use of natural gas the exhaust gases of which are discharged via an over-roof exhaust-gas system approved by the building inspection authorities or via an exhaust-gas pipe tested together with the appliance.
More

Policy

  • Policy Name/Legislation:

  • Policy Type:

    Label Endorsement
  • Mandatory/Voluntary:

    Voluntary
  • Status:

    Under Revision
  • Most Recent Effective Date:

    2011
  • Label Image(s):

Test Procedure

Associated Test Procedure

DIN 4702, Part 8 DIN EN 676

Additional Information

Efficient Energy Utilization
Without making use of a measuring tolerance the nominal utilization ratio according to DIN 4702, Part 8, must not fall below 100% for 10kW and 101% for 70kW at temperatures of 75/60 C°. At temperatures of 40/30°C the nominal utilization ratio must not fall below 103% for 10 kW and 104% for 70kW. Output values between the above limits shall be linearly interpolated according to the formula:
"y = (1/60) x + 99.83" or "y = (1/60) x + 102.83", resp.

Auxiliary Power Demand
Electric Power Consumption / Current Consumption
The following electric power consumption values must be adhered to:
In the SLEEP Mode: 15 watts
During (normal) operation: 80 watts with fan-aided burner
200 watts with forced-drought burner according to DIN EN 676

Other requirements are defined, covering ther environmental aspects.

For more information see the Basic Award Criteria: http://www.blauer-engel.de/en/products_brands/survey_basic_award_criteria.php?objective=2
More

Related Policies

Economy Economy is lorem ipsum text here Product Product is lorem ipsum text here Policy Policy is lorem ipsum text here
Policy Type Policy Status Most Recent Effective Date
IDManifestation IDEconomy NameEconomy IDProduct GroupProduct TypeProduct SubtypePolicy TypePolicy Type IDProduct IDPolicy StatusPolicy Status IDSectorSector IDMandatoryMost Recent ImplementationOrganization NameOrganization URLScopePolicy NamePolicy URL

Canada

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Multi-Sector

Minimum Energy Performance Standard

Entered into Force - No Activity

2008

Japan

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Minimum Energy Performance Standard

Entered into Force - No Activity

2002

Germany

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Endorsement

Under Consideration for Revision

2011

Iran

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Industrial

Label Comparative

Entered into Force - No Activity

Unknown

United States

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Commercial

Minimum Energy Performance Standard

Under Consideration for Revision

2008

Korea (ROK)

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Minimum Energy Performance Standard

Entered into Force - No Activity

2011

Australia

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Minimum Energy Performance Standard

Under Consideration for Development

Unknown

China (PRC)

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Multi-Sector

Label Endorsement

Entered into Force - No Activity

2010

Australia

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Comparative

Under Revision

Unknown

Japan

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Comparative

Entered into Force - No Activity

2006

Israel

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Comparative

Entered into Force - No Activity

2013

Sweden

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Endorsement

Entered into Force - No Activity

2012

Germany

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Multi-Sector

Label Endorsement

Under Revision

2011

Australia

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Minimum Energy Performance Standard

Under Consideration for Development

Unknown

European Union

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Multi-Sector

Minimum Energy Performance Standard

Under Consideration for Development

Unknown

California

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Multi-Sector

Minimum Energy Performance Standard

Entered into Force - No Activity

2008

Iran

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Industrial

Minimum Energy Performance Standard

Entered into Force - No Activity

Unknown

Russia

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Comparative

Entered into Force - No Activity

2012

China (PRC)

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Label Endorsement

Entered into Force - No Activity

2010

United States

Product

  • Group: Heating & Air Conditioning
  • Type: Space Heater

Product Sector

  • Residential

Minimum Energy Performance Standard

Revision Completed - Pending Implementation

2013